Tekbox TBLC08 50µH Line Impedance Stabilisation Network

The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 260V. Conducted noise can be measured on the phase and on the neutral conductor. The TBLC08 is equipped with a switchable limiter/attenuator and an artificial hand connection.
The device is available with country-specific DUT connectors

SKU: tekbox-50µh-line-impedance-stabilisation-network Category:

Description

SPECIFICATIONS

  • Frequency range: 9 kHz to 30 MHz
  • Impedance: 50 Ω ║ (50 µH + 5 Ω)
  • Artificial hand: 220 pF + 511 Ω
  • Switchable PE: 50 Ω ║ 50 µH
  • Limiter / attenuator: 150 kHz to 30 MHz; 10 dB
  • Line voltage: max. 260V / 50 – 60 Hz, CAT ‖
  • DUT socket: country specific
  • Measurement connector: 50 Ω BNC
  • Power connector: IEC 60320 C13
  • Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH
  • Safety: Safety Class I, IEC 1010-01

APPLICATION

  • EMC pre-compliance testing of conducted noise

Additional information

Brands

Tekbox